Diaphragm removal:

1. Unscrew the combined outer extension pipe & cassette chamber (G2 exploded parts 3 & 5) via the nut at the top of the cleaner.

2. Pull the cassette chamber & outer extension pipe out of the G2 Body.

3. Unscrew and separate the cassette chamber & inner extension (G2 parts 5 & 9-11) pipe from the outer extension pipe.

4. Push the inner extension pipe, retaining ring, and diaphragm (G2 parts 9-11) down through the cassette chamber.

5. Wriggle the diaphragm off the inner extension pipe.

6. Remove the plastic retaining ring on the diaphragm. If this is also broken, it will need replacing.

Diaphragm Assembly:

1. Place the plastic retaining ring on the grove on the diaphragm.

2. Wriggle the diaphragm onto the inner extension pipe.

3.Pull the diaphragm and inner extension pipe up through the cassette chamber. The diaphragm should end up at the bottom of the cassette chamber.

4. Screw the cassette chamber & inner extension pipe onto the outer extension pipe.

5. Push the combined cassette chamber & outer extension pipe back into the G2 body, and screw it back into place.